●GLC65 Commercial, 90 to 264 VAC Input, 65 Watt Single Output Global Performance Switchers
● General Specifications
●Input Protection:
● Internal AC fuse provided on all units.
● Inrush Current:
● Inrush is limited by internal thermistors. The inrush at 240 VAC averaged over the first AC half-cycle under cold start conditions will not exceed 37 A.
● Temperature Range:
● 0 to 50°C at full rated power.
● EMI Compliance:
● All models include built-in EMI filtering to meet or exceed the emissions requirements of FCC 20870 Class B, CISPR22-Class B and VDE 0871 Class A above 150 kHz. Typical margins >3 dB at all frequencies and line/load conditions.
● Voltage Adjust:
● Factory set on GLC40, however, adjust potentiometer standard on all GLX50 and GLX65.
● Safety:
● All GLC models are approved to UL1950, CSA22.2 No. 450, and EN60950. All GLM models approved to UL2601, CSA22.2 No. 601.1 and EN60601-1.
● Input Current:
● Maximum input current at 120 VAC, 60 Hz with full rated load not to exceed 1.3 A for GLC40, 1.5 A for GLX50, 1.7 A for GLX65 singles and 2.0 A for the GLX55 multis.
● Efficiency:
● 70-94% depending on model.
● AC Input:
● 90-264 VAC, 47-63 Hz single phase.
● DC Output:
● See output rating chart
● Medical Leakage Current: G
● LM50 - 100 μA @ 264 VAC, 60 Hz; GLM65 Singles — 31 μA @ 132 VAC, 60 Hz; GLM65 multis — 80 μA @ 132 VAC, 60 Hz
● Hold Time:
● 15 mS minimum at full load and nominal line (115 VAC).
● Overload Protection:
● Fully protected against short circuit and output overload on all outputs. Short circuit protection is cycling type power limit.
● Output Noise and Ripple:
● 0.5% RMS 1% PK-PK, 20 MHz bandwidth, differential mode.
● Transient Response:
● Main output: 500 μSec typical response time for return to within 0.5% of final value for a 50% load step within the regulations limits of minimum and maximum load, dl/dt<0.2 A/μSec. Maximum voltage deviation is 3.5%.
● Additional Information:
● Contact your local Allied sales representative or www.condorpower.com
●For data processing applications, etc.
● Dim.:
● 3.0"L × 5.0"W × 2.10"D.
● Weight. (Ozs.):
● Single output — 5; Multiple output — 6.5.
● Features
● Cost Effective Power Source
● Universal Input 90-264 VAC
● Two-Year Warranty
● Single and Multiple Output Models
● Overload and Overvoltage Protection
● Built-In EMI Filter
● UL, CSA and IEC Approvals
● Operation at No-Load
● All Units Meet 1 U Height
● CE Marked to LVD UL1950, CSA-C22.2 No. 234 Levele 3, IEL950 and EN60950
● Features:
● 4.1 W/in 3
● Compact (3.0" × 5.0" × 2. 10")
● Ultra-High Efficiency (Up to 94%) Using Patented Technology
● Meets Harmonic Requirements of IEC1000-3-2, Class A
● Conducted EMI Exceeds FCC Class B and CISPR 22 Class B (Commercial Models)
● Two-Year Warranty
● Exempt From Line Harmonics Standard EN61000-3-2
● Commercial Approved to UL 60950, IEC 60950, EN60950, CSA 22.2 No. 60950
● CE Marked to LVD
● Enclosure Available